| Furling System | boom drives |
| drive type | electric |
| furling direction | cw, ccw |
| max. E-length (boom length), approx. | 11 m |
| D1 – mandrel inner diameter | 165 mm |
| D2 – ∅ emergency drive wheel | 330 mm |
| L – total length | 1445 mm |
| d – ∅ clevis pin | 40 mm |
| W – clevis width | 66 mm |
| G – clevis depth | 35 mm |
| weight of the drive unit | 74 kg |
| holding torque | 6000 Nm |
| drive torque | 600 Nm |
| max. furling speed | 27 rpm |
| flatten function | |
| nominal supply voltage | 24 V, 48 V |
| max. current consumption 24 V | 80 A |
| max. current consumption 48 V | 40 A |
Mainsail handling at the push of a button.
Application
Reckmann BFE is a complete electric drive system for in-boom furling, enabling the handling of large sails with a small crew or even single-handed. The drive unit is installed internally within the boom mandrel as a compact, sealed system. An emergency drive wheel allows the sail to be furled using a line drive in case of power failure.
Functionality
To hoist the sail, the drive is set to a braked freewheel mode. The sail is then rolled out of the boom conventionally using the main halyard, with only the winch being operated. The defined braking resistance prevents uncontrolled unrolling, for example in gusty conditions.
When lowering the sail, the mandrel inside the boom rotates at the push of a button to furl the sail, while the operator eases the main halyard at the desired speed. The additional flatten function allows immediate, fine retensioning of the luff without opening the locking mechanism, e.g. to approach a reefing point with precision. A strong integrated mechanism securely locks the mandrel and absorbs the forces when sailing reefed.
All components are designed for marine use, featuring seawater-resistant materials and protected cabling (min. IP67).
System Concept
BFE systems are supplied as complete, pre-configured systems including the required control and connection components.
The system includes the following components as standard; see system diagram:
① Drive unit with emergency drive wheel
② Connection cable to the control panel
③ Drive flange
④ Mast cable
⑤ Control panel (1x)
⑥ Electronic control box
System Options
BFE drives are available for 12 V, 24 V or 48 V system voltage, depending on system type, see table below.
All systems are available in cw (clockwise) and cw (counterclockwise) configurations. The appropriate configuration is selected depending on whether the sail is to be furled on the starboard (cw) or port side of the boom (ccw).
Accessories
The following optional parts are available:
The system locks automatically after the operation and safely holds the load when the sail is reefed. Additionally, the ratchet geometry allows fine adjustment of the luff without unlocking (flatten function).
The drive unit is fully integrated within the boom mandrel. This saves space, protects the system, and simply looks great.
[Note: Image does not show the standard emergency drive wheel]
The system can be operated remotely for even easier handling, allowing the sail to be controlled from a convenient position on board.
The system is equipped as standard with a drive wheel mounted at the front, allowing manual furling of the sail using a line. The toothed design of the wheel ensures a secure grip, so the mandrel can be rotated reliably even without electrical power.
For BFE-165 and larger models, the emergency drive wheel is supplied in a split, removable design. It can be fitted when required and removed during normal operation.
BFE-100, BFE-125 and BFE-165 are equipped with an emergency release, which can be operated using a standard 8mm hex key. This ensures safe and simple manual operation at any time.
The BFE-125, BFE-165 and BFE-200 feature an integrated locking mechanism with freewheel geometry in the furling direction. This allows the sail to be manually furled via the emergency drive wheel, even without releasing the lock.
Applies for BFE-100, BFE-125, BFE-165
Download: QGREM_BFE-100-125-165_V2.0x_2025_03_TP_comp.pdfApplies for BFE-100, BFE-125, BFE-165
Download: Manual_BFE-100-125-165_V2.0x_2025_04_SN_TP_comp.pdf* By loading the video, you accept Google's privacy policy. Learn more.